Why monitor groundwater?
  • Measure depth to watertable.
  • Measure trends of watertable and salinity.
  • Understand the causes of salinity.
  • Monitor the effectiveness of salinity management options.
When to monitor groundwater?
  • Measure water levels monthly or as specified.
  • Measure at the same time each period.
  • Bail or flush the bore annually, but always prior to salinity measurement.

Photo: Bore monitoring

Figure 1. Bore monitoring

Definitions

Salinity management options - the adoption of perennial pastures, tree lots etc.

Bailer - plastic tube with a hole and ball bearing valve used to sample the groundwater

Photo: Bailer

Figure 2. A bailer

Fox Whistle - hollow metal or plastic tube with narrow air hole suspended at the end of a measuring tape. Make sure the fox whistle is calibrated correctly - the base should be equivalent to 0 cm on the tape.

Photo: Fox Whistle

Figure 3. A Fox whistle

Casing - PVC pipe that forms the wall of the bore, often protected by a steel cover at the surface.

How to measure groundwater depth?
  • Lower the fox whistle into the bore.
  • Stop lowering when the first whistle is heard, pull tape up slightly, and jiggle up and down to accurately establish the depth of whistle, hence groundwater level.
  • Read the depth off the tape at the top of the casing, check zero is the bottom of the whistle.
  • Record depth in the groundwater data booklet.
How to measure salinity?
  • Lower the bailer to the bottom of the bore, allow it to fill and withdraw it.
  • Clear any muddy water at the bottom of the bailer by pushing the ball valve up slightly to release it.
  • Rinse the measuring vessel with the bore water and fill with bore water.
  • Put the EC meter in the water so the electrodes are covered, take the reading and record. Remember to record the units (usually S/cm).
Photo: Hand held EC meter

Figure 4. A hand held EC meter

Looking after your bore
To maintain meaningful records and ensure bore life, make sure:-
  • The vented bore lid is always in place, to prevent debris and rainfall entering.
  • The casing is in good condition. The bore may be prone to damage from vandalism and / or livestock.
  • The bore is stable in the ground. If not, it may need to be cemented.
  • The bore is marked and labelled, according to the CLPR system.
What to do with the data collected?
Record sheets should be forwarded to your NRE Salinity Extension Officer or CLPR every 6 months.

Your information is entered into the statewide dryland salinity groundwater database at CLPR in Bendigo, where it is used by hydrogeologists to interpret groundwater trends and processes.

Monitoring equipment can be obtained from NRE or through CLPR.

Further information
For further information contact your NRE Salinity Extension Officer or CLPR, NRE Bendigo ph. 5430 4444.


The advice provided in this publication is intended as a source of information only. Always read the label before using any of the products mentioned. The State of Victoria and its employees do not guarantee that the publication is without flaw of any kind or is wholly appropriate for your particular purposes and therefore disclaims all liability for any error, loss or other consequence which may arise from you relying on any information in this publication.


Page Top