Introduction
Essential to responsible water management on the farm is the understanding of where and how much is used. This requires the ability to measure it.
Water used in a dairy shed is considered a commercial use of water under the Water Act (1989). Any water used in the dairy sourced from a watercourse, dam capturing overland flow, spring or ground water (bore) requires a licence from the relevant water authority. Rain water captured from a roof, town water and any recycled or reused water is exempt and does not need to be licensed.
Knowing how much water is used helps with planning water needs, storage requirements and potential improvements to the security of supply, particularly during times of shortages. It can also be useful in identifying where water savings can be made.
An important consideration is using water suitable for the purpose. Understanding how water flows through the dairy shed can help identify points where water can be reused.
Processes in the dairy
There are a range of processes in the dairy, each requiring varying amounts of water of differing qualities.
Table 1: Requirements of water for different processes in the dairy
| Vat and machine washing |
Requires comparatively small volumes of the highest quality water, such as rainwater. |
|
Milk cooling |
This can be the biggest use of water in the dairy if no recycling of the water occurs. However, when the water is recycled the net volume of water used in the plate cooler is very small. Requires high quality water. The water can be recycled and continuously used for this purpose providing there is a sufficient volume to ensure effective heat exchange. |
|
Pit activities and shed cleaning |
Requires water of adequate quality for hosing down, but not necessarily as good a quality as rainwater. Generally, fresh or first use water needs to be used; however recycled water from milk cooling could be used. Recycled effluent can not be used inside the shed for hygiene reasons. |
|
Platform sprays |
Mainly associated with rotary dairies. Can require a large amount of water. Water quality needs to be similar to that for the pit activities and shed cleaning. |
|
Yard washing |
Can account for a large proportion of the water used. Water does not necessarily need to be of a high quality and recycled liquid effluent may be used, which can save significant amounts of fresh water. |
|
Other (cooling sprays etc) |
These often use comparatively small amounts of water, but can add up over a milking. |
The processes that require large amounts of water, such as yard washing, milk cooling and fixed platform sprays are the areas where there is largest potential to save water through reuse and recycling.
Understanding how the water flows through the shed
Drawing the water flow helps to understand how water flows through the dairy (See Figure 1). This can also help determine where and how to measure the water use.
|
Measuring water use in the dairy
There are three different methods of measuring water use in the dairy, depending on how the water flows through the dairy.
- Tank method – this is appropriate where tanks are used to store water prior to dairy use.
- Flow rate method – only applicable if the tank method cannot be used,
- Meter/s –Only a small proportion of dairies have meters installed, and these will only measure licensed water, which does not include rainfall from roofs.
For the tank and flow rate method it is important to measure the daily water use during mid lactation to give an average water use for the year. Each method will give reasonable approximation, but won’t be absolutely accurate.
Tank method
Generally water use can be measured via this method if some or all of the water for use in the dairy comes out of a tank/s.You cannot use this method if the tank is filled during milking, such as from a bore.
Steps for each tank:
- List the processes that rely on this tank;
- Calculate the volume of the tank (see diagram below for example);
- Either ensure the tank is completely full at the start of milking or at a known level;
- Turn off any taps to stock troughs etc. You must also remember to turn them back on at the end of milking,
- After milking determine the proportion of the tank used and calculate the volume of water used. Remember different amounts of water may be used for morning and afternoon milkings, so measure both;
- Add the volumes for the morning and afternoon milkings to calculate the daily water use;
- Multiple the daily water use by the number of milking days per year which is often 300 – 320 days;
- Record the volume for the processes that rely on this tank, in the running tally sheet (on page 6).
|
Flow rate method
The flow rate method will need to be used to determine the water use for each process, such as pit hose, yard hose and teat sprays, that is not supplied by a tank. It is important to work out the flow rate for each hose used, as they may vary substantially.
Steps for each hose:
- Time how long it takes to fill a suitably sized container of a known volume such as a 20 litre bucket or 100 litre cherry barrel;
- Divide the litre volume of the container by how long many seconds it took to fill to determine the flow rate (L/sec),
- Multiply by 60 (L/min),
- Determine how long each hose is used for the task per day and then multiply by how long per day each hose is used,
- Multiply by the number of milking days per year.
- Repeat these steps for all processes in the dairy.
- Record answers into the running tally sheet (on page 6)
For more detailed information on the flow rate method and how to measure water used for milk cooling such as a plate cooler, refer to the DPI booklet ‘Dairy shed water – How much do you use?’
Never try to measure the flow rate from a high volume/pressure source, such as hydrants, as they can deliver 2,000 litres per minute and therefore can be dangerous and pose serious OH&S risks. The pump specifications may provide information on the flow rate for this type of equipment.
For a net volume used, be sure not to double count water (i.e. water that is reused or recycled from another part of dairy shed).
Running Tally Sheet
| Process water is used in: | Water source(s) | Annual volume |
|---|---|---|
| Yard cleaning | ML/yr | |
| Milk cooling | ML/yr | |
| Activities in the pit | ML/yr | |
| Fixed cluster and platform sprays | ML/yr | |
| Milking machine and bulk tank/vat cleaning | ML/yr | |
| Other tasks (Please specify) | ML/yr | |
| Total volume in mega litres (ML) | ML/yr |
Figure 3: Running tally sheet to calculate the total volume of water used in the dairy per year, from the DPI booklet ‘Dairy shed water – How much do you use?’
In some instances a combination of the described methods may be used. For example if you use rainwater from a tank for plant wash, the tank method can be used to determine this volume and the flow rate method can be used to determine the volume used for all other processes.
Don’t forget to include tasks such as cleaning calf feeding equipment. These are small uses, but can add up over the year.
For more detailed information on measuring dairy shed water use, refer to DPI booklet ‘Dairy shed water – How much do you use?’ Copies of the booklet can be obtained from the Department of Primary Industries website: http://new.dpi.vic.gov.au or the Customer Call Centre on 136 186.
Contact
Department of Primary Industries Dairy Services Branch Farm Water Solutions team:
Julie Williams (DPI Ellinbank) Phone 03 5624 2222
Acknowledgements
This Information Note was developed by Rachael Campbell, Farm Services Victoria as part of the Farm Water Solutions project with assistance from Rod Eldridge and Benita Kelsall, May 2011.